Combination of the gamma emission tomography and the virtual point-detector methods for calculating radioactive waste drum by non-destructive assays
- University of Science, VNU-HCM
- Posts and Telecommunications Institute of Technology in Ho Chi Minh city campus
- Kien Giang University
Correspondence to:
Tran Thien Thanh,
University of Science, VNU-HCM.
Email:
phamvanphuc2308@gmail.com.
Published:
2020-02-21
Abstract
In this study, the gamma emission tomography and the virtual point-detector method were combined to calculate the efficiency of the radionuclide inside the radioactive waste drum. Therefore, the radioactivity of the radionuclide inside the waste drum has been calculated. The results showed that the source location was determined by the gamma emission tomography for good results with the experimental value. The discrepancies between measured and true activity were smaller than 13% for the sand matrix.