Original Research Open Access Logo

A rapid method using the gamma scattering technique to estimate the pipe-line thickness

Võ Hoàng nguyên 1, 2
Huỳnh Đình Chương 3, 2
Nguyễn Duy Thông 1, 2
Huỳnh Thanh Nhẫn 1, 2
Nguyễn Hữu Bảo 1, 2
Lê Thị Thu Thảo 1, 2
Trần Thiện Thanh 1, 3, 2, *
Châu Văn Tạo 1, 3, 2
  1. Department of Nuclear Physics, Faculty of Physics and Engineering Physics, University of Science, Ho Chi Minh city, Vietnam
  2. Vietnam National University, Ho Chi Minh city, Vietnam
  3. Nuclear Technique Laboratory, University of Science, Ho Chi Minh city, Vietnam
Correspondence to: Trần Thiện Thanh, Department of Nuclear Physics, Faculty of Physics and Engineering Physics, University of Science, Ho Chi Minh city, Vietnam; Nuclear Technique Laboratory, University of Science, Ho Chi Minh city, Vietnam; Vietnam National University, Ho Chi Minh city, Vietnam. Email: [email protected].
Volume & Issue: Vol. 5 No. 4 (2021) | Page No.: 1686-1693 | DOI: 10.32508/stdjns.v5i4.1126
Published: 2021-11-20

Online metrics


Statistics from the website

  • Abstract Views: 1260
  • Galley Views: 647

Statistics from Dimensions

This article is published with open access by Viet Nam National University Ho Chi Minh City, Viet Nam. This article is distributed under the terms of the Creative Commons Attribution License (CC-BY 4.0) which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.

Abstract

In measurements to detect defects inside the materials by gamma-scattered technique, the single scattering intensity was often noticed. However, the spectrum processing to determine single scattering intensities was time consuming, which was detrimental to quick tests. This study aimed to use the total scattering intensity to determine the thickness of the material. In experimental measurements, the total scattering intensity can be determined directly without spectrum processing, thereby shortening the sample inspection time. To calculate the thickness of the material, the total scattering intensity ratio R = Ix/IRef was used. A standard curve of R against the material thickness was built from simulation data using MCNP6. The gamma scattering measurement system used a NaI(Tl) detector, a radioactive source 137Cs, the scattering targets were steel pipes with an outer diameter of 273 mm, a scattering angle of 120o. Based on the standard curve of R, the thickness of the real steel pipes was ditermined by experimental gamma scattering. The results showed that the thickness of steel pipes was determined with a deviation of less than 4% compared to reality. In addition, the calculations also showed that the saturation thickness of steel for the total scattering intensity was significantly larger than that of the single scattering intensity, thereby extending the limit on the thickness of the samples to be measured.

Sorry, we can not display full-text of this article in HTML format for you right now. Please get the article in PDF format instead.

Comments